PRODUCTS

Standard platforms. Controlled customization. Complete power systems.

Medium Voltage Switchgear

  • Metal-Clad Switchgear (5-38kV)
  • Outdoor Gas-Insulated Switchgear (GIS)
  • Gas-Insulated Switchgear (GIS)
  • Arc-Resistant Switchgear
  • Load Interrupter Switchgear
  • Medium Voltage Automatic Transfer Switch

Low-Voltage Distribution

  • Low-Voltage Switchgear
  • UL 891 Switchboards
  • Power & Lighting Panelboards
  • Commercial Power Distribution

Motor Control & Automation

  • Low-Voltage Motor Control Centers
  • Medium Voltage Motor Control
  • MCC Buckets & Replacement Units
  • Motor Control Panels
  • VFD & Soft Starter Panels
  • PLC & Automation Control Panels
  • Pump, Generator, Lighting & Industrial Control Panels
  • Enclosed Control
  • ECB Enclosed Circuit Breakers
  • ENF & EF Enclosed Disconnects

Hazardous-Location & Enclosures

  • Explosion-Proof Panelboards
  • Explosion-Proof Motor Control
  • Explosion-Proof Breakers & Disconnects
  • Hazardous-Location Control Stations
  • NEMA 7 Explosion-Proof Enclosures
  • NEMA 1 / 3R / 4 / 4X & Custom Enclosures
  • XCPLC Explosion-Proof Lighting Contactors

Packaged Power Solutions

  • Switchracks & Skids
  • E-Houses & Power Distribution Centers
  • Switchgear & Switchboard Buildings
  • Control Rooms & Operator Shelters
  • Temporary Power & Power Carts

Busway & Bus Systems

  • Segregated & Non-Segregated Bus Duct
  • Power Connect Bussed Gutter
  • LV & MV Cable / Generator Tap Boxes

RELATED CAPABILITIES Custom engineering certified drilling & tapping testing retrofits system integration

Product families stay under Products. Processes and services stay under Capabilities or Services

Explosion-Proof Lighting Contactor by Spike Electric

XCPLC Explosion-Proof Lighting Contactors

Photocells are shipped separate for field installation.
* Additional configurations are available upon request. Please contact Customer Service for details.
** Timer and/or terminal block will require a larger enclosure (121808).
All entries are plugged as standard.

  • Areas requiring safe and efficient variable lighting control
  • Areas with hazardous gas, vapors and dust
  • Indoor or outdoor locations in damp, wet, dusty or corrosive environments
  • Variable lighting control utilizing manual on/off or automatic settings
  • Photocell option provides maximum utilization of sunlight for energy conservation
  • Modular lighting contactor design provides flexibility to add future power poles
  • Lighting contacts are electrically held for superior performance
  • Power poles convert from NO to NC with a simple 180° turn
  • 081006 enclosure with mounting plate, hinges and breather/drain. Lighting contractors greater then 4 poles will be a 121208 enclosure.
  • Captive, triple lead, quick release, hex head stainless steel bolts with spring-loaded action
  • Tap-in mounting feet offer simple and secure installation and are easily replaceable
  • Special neoprene cover gasket provides a watertight seal to meet NEMA requirements
  • Internal neutral and ground bar
  • Electrically held modular lighting contactor
  • Two ¾” NPT control conduit entries – one on top and one on bottom
  • Twelve 1” NPT power conduit entries – six on top and six on bottom
  • DSL nameplates are standard for all operator positions and Lamacoid nameplates are available upon request
  • Class I, Divisions 1 & 2, Groups B, C, D
  • Class I, Zones 1 & 2
  • Class II, Division 1, Groups E, F, G
  • Class II, Division 2, Groups F, G
  • Class III
  • NEMA 3, 7BCD, 9EFG
  • UL Standard: 1203
  • cUL to CSA Standard C22.2 No. 30
  • Ex d IIB + H2

Standard Materials:

• Body and cover – copper-free aluminum
• Gasket – neoprene
• Cover bolts – stainless steel
• Hinges – stainless steel

Electrical Ratings*:

• Voltage: 600V
• Coil voltage: 120V
• Amperage: 30A
• Number of poles: 1-12 standard

Options / Suffix:

• Terminal block** …………………………….. TB
• Timer** …………………………………………. TR
• EV2IH20 photocell (120V) ……………… PC1
• EV2IH208 277 photocell (208-277V) .. PC2
• Epoxy finish (external) …………………..S752
• Epoxy finish (internal and external) …S753
• Lamacoid nameplate ……………………… LID
• Heater …………………………………………. R11
• Std. Drain…………………………………… S756
• Std. Breather & Drain…………………..S756V

Photocells are shipped separate for field installation.
* Additional configurations are available upon request. Please contact Customer Service for details.
** Timer and/or terminal block will require a larger enclosure (121808).
All entries are plugged as standard.